2

Burner Baltur TBL P 2 Stage Solar

Burner Baltur TBL P 2 Stage Solar

…the boiler. Air flow regulation for first and second stage by means of hydraulic jack. Comes with 4 and 7-poles connectors, 2 flexible oil pipes, 2 nozzles, 1 flange and…

3

Burner Baltur TBG Single Stage Gas

Burner Baltur TBG Single Stage Gas

…of comburent air flow. Gas regulation by means of a two-stage working valve that is electromagnetically driven. Ability to add a valves seal control device to the train. Comes with…

4

Burner Baltur Sparkgas Series Single Stage Gas

Burner Baltur Sparkgas Series Single Stage Gas

…be removed without having to remove the burner from the boiler. Control of comburent air flow. Gas regulation by means of a two-stage working valve that is electromagnetically driven. Ability…

5

Burner Baltur BTL Single Stage Solar

Burner Baltur BTL Single Stage Solar

…regulating combustion air and blast-pipe. Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler. Manual air flow adjustment….

6

Burner Baltur BTG Series Single Stage Gas

Burner Baltur BTG Series Single Stage Gas

…by the fact that the mixing unit can be removed without having to remove the burner from the boiler. Manual air flow adjustment. Possibility to chose gas train with valve…

7

Burner Riello RL BLU-3 Stage Burner Solar

Burner Riello RL BLU-3 Stage Burner Solar

…penutup peredam udara saat burner dimatikan. burner ini telah dilengkapi dengan electronic device STATUS PANEL, yang memasok diagnostik lengkap: hour counter, ignition meter, identification of trouble shooting. Perhatian khusus telah…

8

Oil Pump Suntec AJ series

Oil Pump Suntec AJ series

…10 – 20 bars (regulator with cut-off function) 10 – 30 bars (regulator without cut-off function). Flow range @ 2850 rpm, 5 cSt, 10 bars : 170 – 260 l/h….

9

Oil Pump Suntec D series

Oil Pump Suntec D series

…D pump incorporates an adjustable pressure regulator without cut-off. Pressure range : 10 – 28 bars. Flow range @ 2850 rpm, 20 cSt, 20 bars : 46 – 94 l/h….

10

Oil Pump Suntec T series

Oil Pump Suntec T series

…the seperate TV valve. Pressure range : 40 bars max. (except T5 : 30 bars max) Flow range @ 2850 rpm, 20 cSt, 20 bars : 1380 – 3900 l/h….


Flameindo (jualburner.com) merupakan pusat penjualan perlengkapan industri. Produk kami meliputi Boiler area, Boiler sparepart, Instrument, dan Tangki proses.


Stockis Flow Meter Air - jualburner.com

☏:082231228385 jual burner FBR stockis Flow meter air Burner Riello stockis Flow meter air Burner Beckett Solenoid Dungs stockis Flow meter air, Jual Oil Pump Suntec danfoss dan jual burner control Siemens Honeywell stockis Flow meter air Jual Burner Gas Solar stockis Flow meter air Solenod Regulator gas filter

Stockis Flow Meter Oli - jualburner.com

☏:082231228385 jual burner FBR stockis Flow meter oli Burner Riello stockis Flow meter oli Burner Beckett Solenoid Dungs stockis Flow meter oli, Jual Oil Pump Suntec danfoss dan jual burner control Siemens Honeywell stockis Flow meter oli Jual Burner Gas Solar stockis Flow meter oli Solenod Regulator gas filter

TransPort PT900 Portable Ultrasonic Liquid Flow Meter ...

The Panametrics TransPort PT900 is BHGE's newest portable ultrasonic flow meter. It is a clamp-on flow meter that attaches fixtures with transducers onto the outside of a pipe to measure flow within the pipe without cutting into the pipe or shutting down the process.

PanaFlow Ultrasonic Gas Flow Meter System - industrial.ai

The PanaFlow ultrasonic gas flow meter system is a high-performance, yet affordable solution for a variety of gas flow applications. It consists of two models, the one-path PanaFlow Z1G and the two-path PanaFlow Z2G. Both offer accuracy, rangeability and reliability in robust, sleek meter designs.

Theoretical Fluid Mechanics: Venturi Meter – Mike Soltys ...

Theoretical Fluid Mechanics: Venturi Meter. Posted on March 15, 2011April 4, 2012 by. A Venturi Meter is a device that allows flow rates through pipes to be calculated by measuring the difference in pressure created by a contraction in a pipe. When the flow goes through the contraction it must speed up, and so the pressure must drop.